Id Code Select the type of water source being inspected Select the agency inspecting this water source Enter the date of source inspection Region District Enter the name of settlement / village where the source is located Distance to nearest settlement (KM) Select the agency that established this water source Enter the date when the source was established Enter the water source name Source gpspoint Enter water source Latitude in decimal degrees Enter water source Longitude in decimal degrees Enter Elevation (m.a.s.l) Enter GPS Precision (m) Enter number of water sources in a cluster Water Source Photographs Select the category of users for this water source Is this a permanent status water source? For how many months in a year is this water source in use (#)? Is this water source currently functioning? Non functioning reason No. of persons using No. of Camels using the source No. of Cattle using the source No. of Sheep/Goats using the source Area irrigated using the source (ha) Is the source protected? What is the depth of this borehole (m)? Type of Casing Casing size (inches) What is the current static water level of this borehole (m)? What is the yield of this borehole (m3/hr)? How long is this borehole operated in a day (hr)? What is the borehole draw down (m)? After pumping, how long does this borehole take to recover (hr)? What is the depth of this dug well (m)? What is the current static water level of this dug well (m)? What is the yield of this dug well (m3/hr)? How long is this dug well operated in a day (hr)? What is the dug well draw down (m)? After pumping, how long does this dug well take to recover (hr)? What is the depth of this dam (m)? What is the length of this dam (m)? What is the width of this dam (m)? What is the depth of this berkad (m)? What is the length of this berkad (m)? What is the width of this berkad (m)? What is the cumulative discharge rate of this spring (m3/hr)? What is the depth of this source (m)? What is the length of this source (m)? What is the width of this source (m)? What is the yield of the source (m3/hr)? What type of reservoir is used for this source? Reservoir capacity (m3) Pipeline type Pipeline length (m) How many House Holds (HH) are connected to this water source? How many kiosks/water points are connected to this source? How many animal troughs are connected to this source? Source used for water trucking during emergency? No. of trucks / day Average truck capacity (m3) Pump type Pump model Pump capacity (m3/hr) Pump level (m) Power source Generator/Solar type Generator capacity (kVA/kWh) What type/model is the solar used? What capacity is the solar (kWh)? Condition of supply system Additional notes on supply & distribution system condition Any visible physical problem (color, odor)? Please describe the color, odor and smell of water Temperature PH Electrical Conductivity (µs/cm) Total Dissolved Solids (mg/l) Water sample code. (if taken) Management type Water & Sanitation Committee (WSC)? Year established WSC members male WSC members female DIs water for human use charged? Current cost of 20 ltr jerrican (USD/20ltr) Is water for animal use charged? Current cost for Livestock (USD/100ltr) What is the name of the operator/caretaker for this water source? What is the phone number of the operator/caretaker? Which agency carried out last intervention on this water source? Recent interventions Last intervention date Proposed intervention description Additional Notes Metadata Tag
7972 Borehole Somaliland MoWRD 4/23/2022 Sanaag laasqoray Dhahar 2.0 Community 22/03/2021 Dhahar Borehole 2 9.746539 48.823315 920.0 2 rural urban yes Yes 21000 19000 5390 25000 0.0 280.0 gi 8.0 240.0 25.0 12.0 90.0 1.0 Concrete/Masonry tank 30.0 Galvanised Steel 2.0 0 2 3 yes 5 10.0 Submersible Pump Luwara 60.0 90.0 Hybrid - Solar/Generator Parkins 60.0 Grundfos 22.0 good Well functional supply system condition. no 28.0 6.9 2000.0 560.0 Communal no no no 0 1.New solar panels instalation. 2. New Generator
8099 Borehole Somaliland MoWRD 4/23/2022 Sanaag laasqoray Mindhicir 2.0 ACTED 19/11/2019 Mindhicir borehole 10.122011 48.411472 1055.0 1 rural urban yes Yes 3500 17000 1900 24000 0.0 360.0 gi 8.0 160.0 40.0 12.0 100.0 0.0 Concrete/Masonry tank 40.0 Galvanised Steel 200.0 0 3 2 yes 7 10.0 Submersible Pump Luwara 11.0 160.0 Hybrid - Solar/Generator Parkins 45.0 Sundos 325.0 good Effective and efficient water supply conditions. no 22.0 7.3 1200.0 394.0 Communal no no no 15/04/2022 1. Pump replacement 1. Watch man room 2. Ten new solar pannels Installation.
7597 Borehole Somaliland MoWRD 4/22/2022 Woqooyi Galbeed gebiley Botor 0.1 UNICEF 20/05/2014 Botorwajale borehole 2 9.696804 43.520393 1512.0 0 rural urban yes Yes 10500 60 200 250 0.0 140.0 gi 8.0 89.0 55.0 18.0 0.0 0.0 40.0 PVC 20.0 750 1 2 no Submersible Pump Grundfos 30.0 120.0 Hybrid - Solar/Generator Linz 160.0 Solar 93.6 fair The condition of supply system of this borehoke fair enough no 30.0 7.1 1294.0 916.0 Communal no yes 0.03 no No intervention carried out Pump replacement
7111 Borehole Somaliland MoWRD 4/22/2022 Woqooyi Galbeed gebiley Jameecada 0.1 UNICEF 19/05/2005 Jameecada borehole 1 9.689909 43.647934 1437.0 0 rural yes Yes 1400 500 700 1500 0.0 127.0 gi 8.0 63.0 4.0 8.0 0.0 0.0 Steel tank 12.0 Galvanised Steel 100.0 200 0 1 no Submersible Pump Grundfos 5.0 98.0 Solar Solar power 6.6 good Condition of supply is good no 30.0 7.4 2180.0 1540.0 Communal no yes 0.06 yes GIZ 18/04/2021 Solar instalation Elevated tank, kiosks.
8040 Borehole Somaliland MoWRD 4/22/2022 Sanaag laasqoray Ceel buh 1.0 Horn Relief Ceelbuh borehole3 10.23609 48.31101 1104.0 1 rural urban yes Yes 1200 1300 750 1700 0.0 240.0 gi 8.0 230.0 1.5 12.0 20.0 24.0 Concrete/Masonry tank 35.0 Galvanised Steel 500.0 1 2 3 yes 2 10.0 Submersible Pump Luwara 40.0 75.0 Generator Parkins 45.0 poor Inadeqauate water supply system no 31.0 7.7 1450.0 1000.0 Communal no no no O 1.New pump Installation 11 kvA 2.Generator 45 kW 3.Replacement Gi Piple class c
8110 Borehole Somaliland MoWRD 4/22/2022 Woqooyi Galbeed gebiley Botor 0.1 Dp world 22/04/2022 Botor 9.69366 43.515057 1523.0 0 rural urban yes Yes 1000 0 40 100 0.0 140.0 gi 8.0 89.0 60.0 3.0 0.0 0.0 145 0 0 yes 6 30.0 Submersible Pump Grundfos 30.0 115.0 Generator Perkins 65.0 The condition of supply system in this water source is fair becouse the construction of the road between wajale and kalabaydh depends on. no 28.0 7.2 1154.0 790.0 Communal no no no No intervention required
8112 Borehole Somaliland MoWRD 4/22/2022 Sanaag laasqoray Ceel buh 5.0 Community 22/04/2019 Ceel buh borehole 4 10.241516 48.325386 1091.0 1 rural urban yes Yes 700 4500 300 3750 0.0 295.0 gi 8.0 160.0 10.0 12.0 55.0 0.5 Concrete/Masonry tank 10.0 Galvanised Steel 100.0 0 2 2 yes 20 10.0 Submersible Pump Luwara 45.0 250.0 Generator Parkins 45.0 good Good water supply system condition. no 33.0 7.6 1150.0 1100.0 Communal no no no 0 1.Animal trough camel/cattle
7594 Borehole Somaliland MoWRD 4/22/2022 Woqooyi Galbeed gebiley Botor 0.1 UNICEF 18/07/2014 Botor wajale 1 9.69662 43.52151 1509.0 0 rural urban yes Yes 10500 300 2000 5000 0.0 180.0 gi 8.0 89.0 50.0 17.0 0.0 0.0 Concrete/Masonry tank 40.0 PVC 20.0 750 1 2 no Submersible Pump Grundfos 35.0 140.0 Hybrid - Solar/Generator Linz 160.0 Ja solar 93.6 good Very good and fair condition of supply system. no 30.0 7.4 2200.0 1570.0 Communal no yes 0.03 no No intervention carried out Pump replacement
8117 Borehole Somaliland MoWRD 4/22/2022 Sanaag ceerigaabo Hadaftimo 2.0 NRC 22/04/2020 Hadaftimo Borehole1 10.7432995 48.110043 1375.0 1 rural urban yes Yes 400 350 270 930 0.0 357.0 pvc 8.0 15.0 12.0 0.0 15.0 Concrete/Masonry tank 25.0 Galvanised Steel 1200.0 0 2 2 no Submersible Pump Luwera 11.0 60.0 Generator Parkin 45.0 good Good conditions of water supply system. no 33.0 7.5 1100.0 1600.0 Communal no no no 0 1. New solar Installation
7235 Borehole Somaliland MoWRD 4/22/2022 Woqooyi Galbeed gebiley Jameecada 0.1 Ina Boore 19/06/2005 Jameecada borehole 2 9.6794405 43.646034 1441.0 0 rural yes Yes 2000 0 1000 1500 0.0 150.0 gi 8.0 56.0 4.0 3.0 14.0 2.0 Concrete/Masonry tank 25.0 Galvanised Steel 100.0 285 1 3 no Submersible Pump Grundfos 4.0 143.0 Generator Linz 50.0 good The condition of supply system is all most fair. no 30.1 7.5 2120.0 1500.0 Communal no yes 0.06 yes 19/04/2017 Tank, animal troughs, machine.kiosk, rehabilitation of caretaker room Solar instalation, fittings.